Supports 24 Ethernet ports including 8×2.5G SFP optical ports
Any two ports can form a self-healing ring; multiple independent rings supported
Supports QoS (IEEE 802.1p/1Q and ToS/DiffServ)
Supports SNMPv1/v2c/v3
The TCC4100 series 24-port high-end DIN-rail Layer-3 industrial switch can be configured with 16 Gigabit copper + 8×2.5G/1.0G/100M auto-sensing SFP. Any two ports can form a self-healing ring; multiple independent rings may use dual fiber, single fiber, twisted pair or any combination; ring recovery < 50 ms (typical).
The TCC4100 series 24-port high-end DIN-rail Layer-3 industrial switch supports IGMP snooping, IEEE 802.1Q VLAN, port-based VLAN, QoS and port mirroring. It is fanless with redundant dual power inputs and supports redundant rings and RSTP/STP to improve system reliability and backbone availability. It offers high stability/reliability with local/remote monitoring of key parameters. Unique extended industrial-grade design suits harsh environments.
The cable is connected, but the port will not come UP / the link is down. What should I check?
+What are the PoE power specifications?
+Which ring protocols are supported, and what is the self-healing time?
+How should I choose between Layer-2 and Layer-3 industrial switches?
+Can non-OEM SFP optical modules work normally?
+How do I restore factory settings if I forget the device login password?
+What are the power supply requirements for industrial switches?
+What are the operating temperature range and protection rating of industrial switches?
+The SRS2000 series rack-mount Layer-2 managed industrial switch supports 4 GE/FE SFP + 24 PoE Gigabit copper, and 4 GE/FE SFP + 24 Gigabit copper, for harsh industrial environments as a cost-effective solution. Operating temperature -40°C~ +75°C.
High-performance, flexibly configurable wire-speed switch
Provides packet-loss protection and fast recovery from network faults
Any two ports can form a self-healing ring , and multiple independent self-healing rings
Supports multiple multicast protocols with strong security
Supports IGMP snooping and GMRP
Supports QoS (IEEE 802.1p/1Q and ToS/DiffServ)
Supports SNMPv1/v2c/v3
All-black with Centauri software, 24-port DIN-rail Layer-3 industrial switch: 16×10/100/1000BaseT + 8×2.5G/1.0G/100M auto-sensing SFP, redundant dual isolated power (24~240VDC or 100~240VAC). One relay alarm output (250VAC 2A@250VAC or 125VDC 2A@30VDC) plus management Console. Operating temperature -40°C ~ +85°C; IP40.
Redundant dual power input design
Fanless , -40℃ to +85℃operating ambient temperature
MTBF reaches 600,000 hours
IEEE 802.3 CSMA/CD method and physical Layer specifications CSMA/CD method and physical layer specifications
IEEE 802.1p Priority Queuing Priority Queuing
IEEE 802.1q VLAN tagging VLAN Tagging
IEEE 802.1d Spanning Tree Algorithm Spanning Tree Protocol
IEEE 802.1w Rapid Spanning Tree Rapid Spanning Tree Protocol
IEEE 802.1s Multiple Spanning Tree Multiple Spanning Tree Protocol
IEEE 802.1x Authentication Authentication
IEEE 802.3ac VLAN Tagging VLAN Tagging
IEEE 802.3ad Link Aggregation Link Aggregation
IEEE 802.3x Flow Control Flow Control
IEEE 802.3 Ethernet Ethernet
IEEE 802.3u Fast Ethernet Fast Ethernet
IEEE 802.3z Gigabit Ethernet Gigabit Ethernet
IEEE 802 Networks Networks
RFC 768 UDP User Datagram Protocol
RFC 791 IP Internet Protocol
RFC 792 ICMP Internet Control Message Protocol
RFC 793 TCP Transmission Control Protocol
RFC 826 ARP Address Resolution Protocol
RFC 854 Telnet Client & Server Telnet Client & Server
RFC 862 Echo Protocol Echo Protocol
RFC 863 Discard Protocol Discard Protocol
RFC 1027 Using ARP to Implement Transparent Subnet Gateways Proxy ARP
RFC 1058 RIP Routing Information Protocol
RFC 1059, 1119 NTPv1/2 Network Time Protocol v1/2
RFC 1112 IGMP Host Extensions for IP Multicasting
RFC 1191 Path MTU Discovery Path MTU Discovery
RFC 1256 ICMP Router Discovery Protocol ICMP Router Discovery Protocol
RFC 1388 RIP Version 2 Carrying Additional Information Routing Information Protocol v2
RFC 1519 CIDR (Classless Inter-domain Routing) Classless Inter-Domain Routing
RFC 1542 Bootstrap Extensions & DHCP DHCP relay agent
RFC 1587 OSPF NSSA OSPF
Full aluminum alloy all-black with Changzheng Centauri software, TOM1000 series 10-port Layer-2 industrial switch; corrosion-/oxidation-resistant, never rusts. 2×100/1000/2500BaseX SFP (modules not included) + 8×PoE/PoE+ 10/100/1000BaseT, 1 CLI. IP30; operating temperature -40~75°C; MTBF≥400,000 hours. Redundant dual DC isolated power (48~54VDC). DIN-rail included.
RFC 1812 Requirements for IP Version 4 Routers Requirements for IP Version 4 Routers
RFC 1851 The ESP Triple DES Transform ESP Triple DES Transform
RFC 1994 PPP Challenge Handshake Authentication Protocol (CHAP) Challenge Handshake Authentication Protocol
RFC 2068 HTTP Hypertext Transfer Protocol
RFC 213 DHCP Server DHCP Server
RFC 2138 RADIUS Remote Authentication Dial-In User Service
RFC 2139 RADIUS Accounting RADIUS Accounting
RFC 2236 IGMPv2 IGMPv2
RFC 2328 OSPF V2 OSPF v2
RFC 2338 VRRP Virtual Router Redundancy Protocol
RFC 2370 The OSPF Opaque LSA Option
RFC 2474 DiffServ Precedence
RFC 2475 DifffServ Core and Edge Router Functions
RFC 2597 DiffServ Assured Forwarding
RFC 2598 DiffServ Expedited Forwarding
RFC 2644 Directed Broadcasts Directed Broadcasts
RFC 2865 Remote Authentication Dial In User Service (RADIUS) Remote Authentication Dial-In User Service
RFC 3046 DHCP Relay Agent Information Option DHCP Relay Agent Information Option
RFC 3222 Forwarding Information Base (FIB) Forwarding Information Base
GMRP GARP Multicast Registration Protocol
GVRP GARP VLAN Registration Protocol
SSH2 Secure Shell 2
IGMP snooping IGMP snooping
SNMPv3 Simple Network Management Protocol v3
| Backplane bandwidth | 72Gbps |
| Processor | 333MHz RISC |
| Switching Technology | ASIC-based store-and-forward |
| MAC address table | 16K |
| packet buffer | 4 Mbits |
| switching rate | 148,800 pps/FE port; 1,488,000 pps/GE port |
| Management Methods | Browser , Serial , STD-17 MIB-II , STD-58 SMIv2 , STD-62 SNMPv3 , SNMPv2c, SNMPv1 , RFC 3636 MAU , RFC 2925 Ping MIB , MRD Private MI Bs |
| Diagnostics | LEDs, log files, relay, port mirroring, TRAP |
| Redundancy | RSTP , MSTP , STP , ERPS , link aggregation , MRP |
| time synchronization | SNTP ,NTP |
| Other | 4K VLANS , IPv4/IPv6 multicast , storm control , MC/BC protection , Supports Jumbo Frame |
| connection | 1 removable 5-PIN terminal block |
| Input voltage | 24~240VDC or 100~240VAC (50~60Hz) , dual input |
| overload current protection | Supports |
| reverse polarity protection | Supports |
| Power consumption | ≤28W |
| Mounting method | Din-Rail mounting |
| housing | die-cast aluminum alloy housing |
| protection rating | IP40 |
| Dimensions (W×H×D) | 88mm x 140mm x 110mm (±3mm) |
| Weight | ≤ 1.4KG |
| MTBF | ≥600,000 H |
| storage temperature | ‐40°C ~ 85°C |
| Operating temperature | ‐40°C ~ 85°C |
| Humidity | 5% ~ 95% (non-condensing) |
| Vibration | IEC 60068-2-6 |
| Shock | IEC 60068-2-27 |
| free fall | IEC 60068-2-31 |
| PCB | Compliant with IPC standards |
| EMI radiation | FCC 47 CFR Part 15 Class A EN55032 Class A EN55035 Class A |
| EMC | IEC(EN)61000-4-2, Level 4 IEC(EN)61000-4-4, Level 3 IEC(EN)61000-4-5, Level 4 IEC(EN)61000-4-8, Level 5 IEC(EN)61000-4-11, Level 4 IEC(EN)61000-4-12, Level 3 |
| Product Safety | CE IEC/EN60950-1 FCC Part 15 Subpart B C lass A |
| hazardous area | UL121201 (certification in progress) |
| transportation industry | JT/T817-2011 |
| rail industry | EN50155;IEC/EN61373; EN50121 |
| power industry | IEC61850-3 IEEE1613(C37.90.x) |
| industrial control industry | UL/cUL61010 |
| shipbuilding industry | GL (certification in progress) |
| Model | Product Specification |
| TCC4100-ISC24U80G0 | Full aluminum alloy all-black with Changzheng Centauri software, TOM1000 series 10-port Layer-2 industrial switch; corrosion-/oxidation-resistant, never rusts. 2×100/1000/2500BaseX SFP (modules not included) + 8×10/100/1000BaseT, 1 CLI. IP40; operating temperature -40~75°C; MTBF≥400,000 hours. Redundant dual isolated power (24~240VDC or 100~240VAC). DIN-rail included. |